Cited 0 time in
1인치 볼 밸브 및 글로브 밸브에 대한 개도율에따른 손실계수(K) 비교에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 강창원 | - |
| dc.contributor.author | 이중섭 | - |
| dc.contributor.author | 이치우 | - |
| dc.date.accessioned | 2022-12-26T11:30:50Z | - |
| dc.date.available | 2022-12-26T11:30:50Z | - |
| dc.date.issued | 2021 | - |
| dc.identifier.issn | 1598-6721 | - |
| dc.identifier.issn | 2288-0771 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/5056 | - |
| dc.description.abstract | This study aims to determine the flow characteristics of a one-inch small ball valve and glove valve used inindustrial plants. The flow was changed through an experimental equipment, and the internal flow characteristicsof the valves were compared. Considering the pressure drop, the decrease in the slope of the ball valve basedon the degree of the valve opening was relatively greater than that of the glove valve; further, the slope of theglove valve was gentle while the pressure drop was high. The flow velocity of the ball valve remainsconsistent after the valve was opened by 70%, whereas the flow velocity of the glove valve constantly increased. The valve loss factor of the ball valve was relatively low compared with that of the glove valve. When thevalve was opened by 20%, which is the beginning stage of the valve opening, the valve loss factor of the ballvalve was high and gradually became low. This is a structural problem of the ball valve, and the loss factor issignificant because the flow path installed at the ball valve has a considerably small area. However, the overallloss factor of glove valve is high because it has a complicated structure of flow path. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국기계가공학회 | - |
| dc.title | 1인치 볼 밸브 및 글로브 밸브에 대한 개도율에따른 손실계수(K) 비교에 관한 연구 | - |
| dc.title.alternative | Comparison of Loss Coefficient using 1-inch Ball and Glove Valve Opening Ratio | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.14775/ksmpe.2021.20.09.063 | - |
| dc.identifier.bibliographicCitation | 한국기계가공학회지, v.20, no.9, pp 63 - 69 | - |
| dc.citation.title | 한국기계가공학회지 | - |
| dc.citation.volume | 20 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 63 | - |
| dc.citation.endPage | 69 | - |
| dc.identifier.kciid | ART002756131 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 볼밸브 | - |
| dc.subject.keywordAuthor | 글로브 밸브 | - |
| dc.subject.keywordAuthor | 밸브 손실계수 | - |
| dc.subject.keywordAuthor | Ball Valve | - |
| dc.subject.keywordAuthor | Glove Valve | - |
| dc.subject.keywordAuthor | Valve Loss Coefficient | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.