Detailed Information

Cited 1 time in webofscience Cited 3 time in scopus
Metadata Downloads

Renal Diffusion-Weighted Imaging in Healthy Dogs: Reproducibility, Test-Retest Repeatability, and Selection of the Optimal b-value Combinationopen access

Authors
Lee, Sang-KwonLee, JuryeoungJang, SeolynLee, EunjiJeon, Chang-YeopLim, Kyung-SeoubJin, Yeung BaeChoi, Jihye
Issue Date
2-Jul-2021
Publisher
FRONTIERS MEDIA SA
Keywords
canine; diffusion-weighted magnetic resonance imaging; kidney; renal fibrosis; b-value
Citation
FRONTIERS IN VETERINARY SCIENCE, v.8
Indexed
SCIE
SCOPUS
Journal Title
FRONTIERS IN VETERINARY SCIENCE
Volume
8
URI
https://scholarworks.bwise.kr/gnu/handle/sw.gnu/3500
DOI
10.3389/fvets.2021.641971
ISSN
2297-1769
Abstract
Diffusion-weighted imaging (DWI) magnetic resonance imaging can evaluate alterations in the microstructure of the kidney. The purpose of this study was to assess the apparent diffusion coefficient (ADC) and the intravoxel incoherent motion model (IVIM) parameters of a normal kidney in healthy dogs, to evaluate the effect of b-value combinations on the ADC value, and the reproducibility and test-retest repeatability in monoexponential and IVIM analysis. In this experimental study, the ADC, pure diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (f (p)) were measured from both kidneys in nine healthy beagles using nine b-values (b = 0, 50, 70, 100, 150, 200, 500, 800, and 1,000 s/mm(2)) twice with a 1-week interval between measurements. Interobserver and intraobserver reproducibility, and test-retest repeatability of the measurements were calculated. ADC values were measured using 10 different b-value combinations consisting of three b-values each, and were compared to the ADC obtained from nine b-values. All the ADC, D, D*, and f (p) values measured from the renal cortex, medulla, and the entire kidney had excellent interobserver and intraobserver reproducibility, and test-retest repeatability. The ADC obtained from a b-value combination of 0, 100, and 800 s/mm(2) had the highest intraclass correlation coefficient with the ADC from nine b-values. The results of this study indicated that DWI MRI using multiple b-values is feasible for the measurement of ADC and IVIM parameters with high reproducibility and repeatability in the kidneys of healthy dogs. A combination of b = 0, 100, and 800 s/mm(2) can be used for ADC measurements when multiple b-values are not available in dogs.
Files in This Item
There are no files associated with this item.
Appears in
Collections
수의과대학 > Department of Veterinary Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jin, Yeung Bae photo

Jin, Yeung Bae
수의과대학 (수의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE