Analysis of Heat and Mass Distribution in a Single- and Multi-Span Greenhouse Microclimateopen access
- Authors
- Ogunlowo, Qazeem Opeyemi; Akpenpuun, Timothy Denen; Na, Wook-Ho; Rabiu, Anis; Adesanya, Misbaudeen Aderemi; Addae, Kwame Sasu; Kim, Hyeon-Tae; Lee, Hyun-Woo
- Issue Date
- Sep-2021
- Publisher
- MDPI
- Keywords
- energy estimation; heat; mass; distribution; greenhouse; microclimate
- Citation
- AGRICULTURE-BASEL, v.11, no.9
- Indexed
- SCIE
SCOPUS
- Journal Title
- AGRICULTURE-BASEL
- Volume
- 11
- Number
- 9
- URI
- https://scholarworks.bwise.kr/gnu/handle/sw.gnu/3342
- DOI
- 10.3390/agriculture11090891
- ISSN
- 2077-0472
- Abstract
- Recently, heat and mass distributions within a greenhouse were assumed to be homogeneous. Heat is gained or lost in absolute terms, and crop contribution in a greenhouse or its effect is not considered. In this study, statistical analyses were conducted to establish the significance of heat and mass variation at sensor nodes in two single-span and multi-span greenhouses. Three greenhouses were used in this study, 168 m(2) floor area a single-layered (SLG), double-layered (DLG) single-span gothic roof type greenhouses, and 7572.6 m(2) floor area multi-span greenhouse (MSG). The microclimatic parameters investigated were temperature (T), relative humidity (RH), solar radiation (SR), carbon dioxide (CO2), and vapor pressure deficit (VPD). To check their horizontal distribution, all microclimate data collected from each sensor node in each greenhouse were subjected to descriptive statistics and Tukey honestly significant difference (HSD) test. The lowest minimum temperatures of 2.93 degrees C, 3.33 degrees C and 10.50 degrees C were recorded at sensor points in SLG, DLG, and MSG, respectively, whereas the highest maximum temperatures of 29.17 degrees C, 29.07 degrees C and 27.20 degrees C were recorded at sensor point, in SLG, DLG, and MSG, respectively. The difference between the center and the side into the single-span was approximately 0.88-1.0 degrees C and in the MSG was approximately 1.03 degrees C. Significant variation was observed in the horizontal distribution of T, RH, SR, and VPD within SLG, DLG, and MSG. Also significant was CO2 in the MSG. Estimating the energy demand of greenhouses should be done based on the distribution rather than assuming microclimatic parameters homogeneity, especially for T, with VPD as a control parameter. Such estimation should also be done using a crop model that considers instant changes in air and crop temperature.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 농업생명과학대학 > 생물산업기계공학과 > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.