Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

How to Solve Anatomical Mismatch in Fixation of Acetabular Fractures Using an Anatomical Quadrilateral Surface Plateopen access

Authors
Cha, Y.Yoo, J.-I.Kim, J.-T.Park, C.H.Choy, W.-S.
Issue Date
Apr-2023
Publisher
NLM (Medline)
Keywords
Acetabulum; Bone plate; Fractures; Reduction
Citation
Clinics in orthopedic surgery, v.15, no.2, pp 338 - 342
Pages
5
Indexed
SCIE
SCOPUS
KCI
Journal Title
Clinics in orthopedic surgery
Volume
15
Number
2
Start Page
338
End Page
342
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/30847
DOI
10.4055/cios22169
ISSN
2005-291x
2005-4408
Abstract
The anatomical quadrilateral surface buttress plate developed for the quadrilateral surface in an acetabular fracture, a type of fracture difficult to reduce using screws and plates due to its thinness, is a useful implant that makes surgical treatment easier. However, the anatomical structure is different for each patient, and it often does not match the contour of this plate, making detailed bending difficult. Here, we introduce a simple method for controlling the degree of reduction using this plate. Copyright © 2023 by The Korean Orthopaedic Association.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE