Effect of envelope characteristics on the accuracy of discretised greenhouse model in TRNSYSopen access
- Authors
- Ogunlowo, Q.O.; Na, W.H.; Rabiu, A.; Adesanya, M.A.; Akpenpuun, T.D.; Kim, H.T.; Lee, H.W.
- Issue Date
- Sep-2022
- Publisher
- Page Press Publications
- Keywords
- Building; Discretisation; Energy; Envelope characteristics; Simulation; TRNSYS
- Citation
- Journal of Agricultural Engineering, v.53, no.3
- Indexed
- SCIE
SCOPUS
- Journal Title
- Journal of Agricultural Engineering
- Volume
- 53
- Number
- 3
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/30071
- DOI
- 10.4081/jae.2022.1420
- ISSN
- 1974-7071
2239-6268
- Abstract
- TRNSYS is a standard tool recently used to model and simulate greenhouse energy demand and utilisation using building energy simulation (BES). Previously, a single thermal point was used for validation, ignoring the distribution of greenhouse climate parameters, especially the temperature. Temperature variation often leads to thermal stratification, prompting researchers to propose volume discretisation in dynamic greenhouse simulations. In this context, the effect of envelope characterisation on the accuracy of the discretised TRNSYS BES model was developed to determine the best BES model under a free-floating regime. The combination of the number of layers [double (D) and single (S)], geometry mode [3D and manual (M)], and layer type [massless (M) and no glazing window (W)], led to the development of five models: D_3D_M, D_3D_W, D_M_M, S_3D_W, and S_M_M. The simulation was performed in a standard radiation mode, and the output parameters were temperature and relative humidity (RH). R2 and the root square mean error (RSME) were used to check the fitness and degree of deviation, respectively, to validate the models. Analysis of variance (ANOVA) was employed to investigate the significant differences among the models, whereas contour plots were used to compare the distribution pattern between the significant models and experimental data. Validation of the models showed that the obtained R2 values ranged from 0.86 to 0.95, and the RSME values for the temperature were between 2.64°C and 3.91°C. These values were 0.91-0.93 and 19.72%-30.32% for RH. The ANOVA (P<0.05) result exhibited significant differences between the S-scenario models and experi-mental central points in temperature and RH. However, the D- and S-layer scenarios with a 3D geometry and massless layer showed similar distribution with their corresponding experimental green-houses. Hence, 3D_M was regarded as the best combination in the discretised BES model. © the Author(s), 2022.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 농업생명과학대학 > 생물산업기계공학과 > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.