맥동압을 가지는 챔버내의 압력변화에 관한 연구Study on the Pressure Variation in a Chamber Caused by Pulsation Pressure

Other Titles
Study on the Pressure Variation in a Chamber Caused by Pulsation Pressure
Authors
이중섭심규진Wanda Ali Akbar정한식정효민
Issue Date
2007
Publisher
한국자동차공학회
Keywords
Buffer plate; Pulsation pressure; CFD; 완충격판; 맥동압; 전산유체역학
Citation
한국자동차공학회 논문집, v.15, no.4, pp 132 - 138
Pages
7
Indexed
KCI
Journal Title
한국자동차공학회 논문집
Volume
15
Number
4
Start Page
132
End Page
138
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/28780
ISSN
1225-6382
2234-0149
Abstract
Experimental results of pulsating pressure behavior inside a chamber have been confirmed by computational work. Inside-cylinder pressure shows unstable condition at low rpm. This is caused by plate-type suction valve. It has effect up to inlet of the chamber. But trembling phenomenon is reduced as the pressure is enlarged by increasing the rpm. Result comparison between experimental and numerical analysis shows pulsation reduction is affected by the chamber. We can confirm that compressible effect of the working flow is shown at chamber inlet by increasing rpm. On the other side, this effect is declined at chamber outlet by increasing rpm. It means outlet pressure is going on balance with atmosphere pressure. Buffer plate-type chamber has efficiency of pulsation flow reduction.
Files in This Item
There are no files associated with this item.
Appears in
Collections
해양과학대학 > ETC > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE