A Novel Communication Method Using PWM and Capture Function of DSP for Parallel Controlled Power Electronics Systemsopen access

Authors
Park, Byung-WooPark, Sung-JunKang, Feel-Soon
Issue Date
Jun-2022
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
Registers; Codes; Pulse width modulation; Protocols; Power conversion; Power system stability; Image edge detection; Digital signal processor (DSP); electric load; MODBUS; power conversion systems; pulse width modulation (PWM); remote terminal unit (RTU)
Citation
IEEE Access, v.10, pp 68266 - 68280
Pages
15
Indexed
SCIE
SCOPUS
Journal Title
IEEE Access
Volume
10
Start Page
68266
End Page
68280
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/2793
DOI
10.1109/ACCESS.2022.3186690
ISSN
2169-3536
Abstract
Parallel operation by multiple power converters is typical in microgrids. The communication method for parallel control mainly applies MODBUS RTU (Remote Terminal Unit), and the control performance largely depends on the communication speed. This paper proposes a new communication method that enables fast and accurate communication between master and slave systems combined in parallel using the PWM and capture functions of DSP used as the power converter controller. In the proposed communication method, the transmitting side uses the PWM function of DSP to generate a pulse waveform whose pulse width changes according to the reference command and transmits it to the receiving side. Suppose the capture function of the receiving side DSP is set to the time difference rising and falling edge mode. The set event occurs when the capture signal is detected and initializes the counter value to zero. At this time, it detects the counter signal and receives data. We explain the proposed communication method's principle, characteristics, and noise-canceling method and evaluate the accuracy and stability through data transmission and reception experiments. Finally, three 10kW single-phase electronic loads are connected to the R, S, and T phases to form a three-phase electronic load, and a master and two slaves are designated. The validity of the proposed communication method is verified through the current control response according to the command.
Files in This Item
There are no files associated with this item.
Appears in
Collections
융합기술공과대학 > Division of Mechatronics Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Feel-soon photo

Kang, Feel-soon
IT공과대학 (메카트로닉스공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE