Cited 3 time in
Development of force measuring system using three-axis force sensor for measuring two-finger force
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, H.-M. | - |
| dc.contributor.author | Yoon, J. | - |
| dc.contributor.author | Shin, H.-S. | - |
| dc.contributor.author | Kim, G.-S. | - |
| dc.date.accessioned | 2022-12-27T05:01:55Z | - |
| dc.date.available | 2022-12-27T05:01:55Z | - |
| dc.date.issued | 2010 | - |
| dc.identifier.issn | 1976-5622 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/26002 | - |
| dc.description.abstract | Stroke patients can't use their hands because of the paralysis their fingers. Their fingers are recovered by rehabilitating training, and the rehabilitating extent can be judged by measuring the pressing force to be contacted with two fingers (thumb and first finger, thumb and middle finger, thumb and ring finger, thumb and little finger). But, at present, the grasping finger force of two-finger can't be accurately measured, because there is not a proper finger-force measuring system. Therefore, doctors can't correctly judge the rehabilitating extent. So, the finger-force measuring system which can measure the grasping force of two-finger must be developed. In this paper, the finger-force measuring system with a three-axis force sensor which can measure the pressing force was developed. The three-axis force sensor was designed and fabricated, and the force measuring device was designed and manufactured using DSP (Digital Signal Processing). Also, the grasping force test of men was performed using the developed finger-force measuring system, it was confirmed that the grasping forces of men were different according to grasping methods. ? ICROS 2010. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.title | Development of force measuring system using three-axis force sensor for measuring two-finger force | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5302/J.ICROS.2010.16.9.876 | - |
| dc.identifier.scopusid | 2-s2.0-84856517907 | - |
| dc.identifier.bibliographicCitation | Journal of Institute of Control, Robotics and Systems, v.16, no.9, pp 876 - 882 | - |
| dc.citation.title | Journal of Institute of Control, Robotics and Systems | - |
| dc.citation.volume | 16 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 876 | - |
| dc.citation.endPage | 882 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001475470 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Finger rehabilitation | - |
| dc.subject.keywordAuthor | Finger-force measuring system | - |
| dc.subject.keywordAuthor | Rehabilitating instrument | - |
| dc.subject.keywordAuthor | Three-axis force sensor | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
