Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

파프리카 재배용 온실에서 용접 파이프 기둥재의 구조적 안전성 검토Analysis of Structural Safety of the Welded Pipe Columns Adopted in Paprika Greenhouse

Other Titles
Analysis of Structural Safety of the Welded Pipe Columns Adopted in Paprika Greenhouse
Authors
서원명최만권임재운권순주김현태김영주윤용철
Issue Date
2011
Publisher
경상국립대학교 농업생명과학연구원
Keywords
강관; 굽힘 강도; 굽힘 시험; 용접 파이프; 1-2W형 온실; Steel pipe; Bending strength; Bending test; Welding pipe; 1-2W type greenhouse
Citation
농업생명과학연구, v.45, no.2, pp 125 - 133
Pages
9
Indexed
KCI
Journal Title
농업생명과학연구
Volume
45
Number
2
Start Page
125
End Page
133
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/24467
ISSN
1598-5504
2383-8272
Abstract
This study was conducted on greenhouses whose side heights had been raised after the columns of 1-2W basic type greenhouses had been cut and welding with the same-sized pipes. When the wind load or snow load affects restructured pipe greenhouse like this, those parts will be structurally unsafe. To examine this, the bending strength of welded columns were measured through four stages and compared with the pipes in their original condition. Results are as follows. In the case of a bending test on welded joints about steel pipes used for greenhouses, satisfactory results couldn’t be drawn because sections of both ends and the loading parts couldn’t endure loads and sank regardless of loading methods. Partial problems could be solved by inserting inside pipe(steel bar) at the sections and the loading parts, but it was necessary to devise more satisfactory bending test methods. The strength of welded joints wasn’t much different compared with original conditions and demonstrated only slight differences according to the sample production conditions. However, significant incompleteness in the welding process was expected to cause a decisive loss in strength. On the assumption that there were no problems in the welding process or with regard to the inclination of sub materials for columns after connection, it was deemed reasonable to assume that the strength of welded pipes was about 84~90% of the strength of the pipes in their original condition. Considering mid- and long-term strength decline following the onset of rust at joints or welding sections, structural changes in the main sub materials that are used for greenhouses at farmhouses have to be avoided to ensure structural safety, unless these changes are inevitable.
Files in This Item
There are no files associated with this item.
Appears in
Collections
농업생명과학대학 > Department of Agricultural Engineering, GNU > Journal Articles
농업생명과학대학 > 생물산업기계공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyeon Tae photo

Kim, Hyeon Tae
농업생명과학대학 (생물산업기계공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE