Cited 0 time in
접선유입식과 축상유입식 사이클론의 집진효율 비교
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이중섭 | - |
| dc.contributor.author | 이치우 | - |
| dc.date.accessioned | 2022-12-27T03:19:45Z | - |
| dc.date.available | 2022-12-27T03:19:45Z | - |
| dc.date.issued | 2011 | - |
| dc.identifier.issn | 1598-6721 | - |
| dc.identifier.issn | 2288-0771 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/24077 | - |
| dc.description.abstract | This study is about comparison of tangental entry type cyclone dust collector with axial vane type cyclone dust collector. Cut diameter and dust collection efficiency of both collector was compared by theory and experiment. Cut diameter was calculated by an quasi-empirical formula by Lapple and Shepherd. Measurement of cut diameter was conducted by particle counter through dust generator. As the result, cut diameter obtained by experiment was a little larger than that by theory. But the error is within 0.5㎛ in both type of collector, so it could be confirmed that theoretical value and experimental value were almost identical. And, as flow rate increased, dust collection efficiency was increased. Also axial vane type showed higher dust collection efficiency than tangental entry type. Therefore, it can be said that axial vane type cyclone dust collector has higher performance than the other. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국기계가공학회 | - |
| dc.title | 접선유입식과 축상유입식 사이클론의 집진효율 비교 | - |
| dc.title.alternative | Comparisons of Dust Collection Efficiency on the Tangental Entry and Axial-vane Type Cyclone | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 한국기계가공학회지, v.10, no.6, pp 115 - 121 | - |
| dc.citation.title | 한국기계가공학회지 | - |
| dc.citation.volume | 10 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 115 | - |
| dc.citation.endPage | 121 | - |
| dc.identifier.kciid | ART001610141 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Tangental Entry type Cyclone(접선유입식 사이클론) | - |
| dc.subject.keywordAuthor | Axial-Vane type Cyclone(축상유입식 사이클론) | - |
| dc.subject.keywordAuthor | Cut Diameter(절단입경) | - |
| dc.subject.keywordAuthor | Tangental Entry type Cyclone(접선유입식 사이클론) | - |
| dc.subject.keywordAuthor | Axial-Vane type Cyclone(축상유입식 사이클론) | - |
| dc.subject.keywordAuthor | Cut Diameter(절단입경) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.