Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

경남지역의 실내외 공기 중 총섬유 입자의 농도특성 및 석면 입자의 확인Concentration Characteristics of Indoor and Outdoor Airborne Total Fiber Particles and Identification of Asbestos in Gyeongnam Provinces

Other Titles
Concentration Characteristics of Indoor and Outdoor Airborne Total Fiber Particles and Identification of Asbestos in Gyeongnam Provinces
Authors
박희은박정호김형갑
Issue Date
2012
Publisher
한국산업보건학회
Keywords
Asbestos; PCM; SEM/EDX; Concentration Characteristics
Citation
한국산업보건학회지, v.22, no.2, pp 119 - 127
Pages
9
Indexed
KCI
Journal Title
한국산업보건학회지
Volume
22
Number
2
Start Page
119
End Page
127
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/22560
ISSN
2384-132x
2289-0564
Abstract
Objectives:The aim of this study is to identify concentration characteristics of indoor and outdoor airborne total fiber particles and asbestos in Gyeongnam Provinces. Methods:This study investigated concentration characteristics of indoor fiber particles from 748 schools and 38 public facilities as well as outdoor particles from 11 sites through PCM (phase contrast microscope). SEM/EDX (scanning electron microscope/energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber particles. The study identified asbestos rate in the 15 samples from indoor and outdoor airborne total fiber particles. Results:1. The average indoor airborne concentrations of total fiber particles were 0.0011±0.0007 f/cc in schools and 0.0015±0.0007 f/cc in public facilities by PCM. Over 90 % of the fiber particles were identified as single fibers. 2. The average outdoor airborne concentrations of total fiber particles were 0.0007±0.0002 f/cc, and they were lower than those of indoor airborne concentrations. 3. The results showed that the form of asbestiform was diverse as skein of thread like form and long needle, which was relatively narrower than that of glass fiber and rock wool. 4. The results of SEM/EDX analysis of 15 areas where total fiber particle was relatively high showed that the form was rather similar to that of asbestos, but chemical composition was proven to be non-asbestos. Conclusions:The concentration of indoor and outdoor airborne total fiber particles of Gyeongnam Provinces satisfied the IAQ (Indoor air quality) level of 0.01 f/cc and asbestos was not found in most of the samples by SEM/EDX.
Files in This Item
There are no files associated with this item.
Appears in
Collections
건설환경공과대학 > 환경공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jeong Ho photo

Park, Jeong Ho
건설환경공과대학 (환경공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE