연속식 미생물연료전지 성능에 미치는 운전변수의 영향Effects of operating parameters on the performance of continuous flow microbial fuel cell

Other Titles
Effects of operating parameters on the performance of continuous flow microbial fuel cell
Authors
정재우최영대이명은송영채우정희유규선이채영
Issue Date
2013
Publisher
대한상하수도학회
Keywords
continuous flow MFC (microbial fuel cell); electricity generation; hydraulic retention time; recycle ratio; influent COD concentration; 연속식 미생물연료전지; 전기생산; 수리학적 체류시간; 반송비; 유입 COD 농도
Citation
상하수도학회지, v.27, no.4, pp 489 - 494
Pages
6
Indexed
KCI
Journal Title
상하수도학회지
Volume
27
Number
4
Start Page
489
End Page
494
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/20966
ISSN
1225-7672
2287-822X
Abstract
Effects of operating parameters such as hydraulic retention time(HRT), recycle ratio and influent COD concentration on the performance of a continuous flow microbial fuel cell(MFC) were investigated. Decrease of HRT improved mass transfer of substrate to electrogenic microorganisms, therefore resulting in increased electrode voltage and power generation of MFC. Increase of HRT promoted COD removal by elongating retention time for COD removal in MFC. Recycling of effluent increased the COD removal and coulombic efficiencies by returning suspended microorganisms into MFC. Increase of influent COD enhanced COD removal due to the improved mass transfer of substrate. Decrease of coulombic efficiency by the increase of the HRT and influent COD concentration indicated that they enhanced the activities of fermentative bacteria.
Files in This Item
There are no files associated with this item.
Appears in
Collections
건설환경공과대학 > 환경공학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Jae Woo photo

Chung, Jae Woo
건설환경공과대학 (환경공학과)