Detailed Information

Cited 9 time in webofscience Cited 9 time in scopus
Metadata Downloads

Evaluation of the URiSCAN Super Cassette ACR Semiquantitative Urine Dipstick for Microalbuminuria Screeningopen access

Authors
Cho, Min-ChulJi, MisukKim, So YoungChoe, WonhoLee, WoochangChun, SailMin, Won-Ki
Issue Date
Jul-2014
Publisher
WILEY
Keywords
microalbuminuria; albuminuria; screening test; urine dipstick; semiquantitative
Citation
JOURNAL OF CLINICAL LABORATORY ANALYSIS, v.28, no.4, pp 281 - 286
Pages
6
Indexed
SCI
SCIE
SCOPUS
Journal Title
JOURNAL OF CLINICAL LABORATORY ANALYSIS
Volume
28
Number
4
Start Page
281
End Page
286
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/18903
DOI
10.1002/jcla.21681
ISSN
0887-8013
1098-2825
Abstract
Background: Microalbuminuria tests are used as screening tools for diseases, such as diabetic nephropathy, cardiovascular disease, and hypertension. The purpose of this study was to evaluate the utility of a newly introduced semiquantitative urine dipstick, URiSCAN Super cassette ACR (URiSuper-ACR [where ACR is albumin/creatinine ratio]; YD Diagnostics Corp., Korea), as a screening tool for microalbuminuria. Methods: Albumin and creatinine levels in randomly selected spot urine samples of 1,040 patients were semiquantitatively measured using URiSuperACR. Results using URiSuper-ACR system were compared to measurements obtained by quantitative analyzer. We also calculated diagnostic sensitivity, specificity, precision, linearity, and categorical concordance rates for the diagnosis of microalbumiuria using this system. Furthermore, we performed interference tests using standard controls to evaluate possible influence of various factors. Results: URiSuper-ACR test showed 88.8% and 86.3% sensitivity and 90.1% and 93.8% specificity for albumin concentration and ACR, respectively. It also showed 91.1% and 92.6% positive predictive values and 87.6% and 88.5% negative predictive values, respectively. The concordance rate between URiSuper-ACR and quantitative method for albumin and creatinine concentration within the same category were 78.4% and 67.1%, respectively, and for the +/- 1 category were 98.8% and 99.5%, respectively. For ACR, an 80.0% concordance rate was seen within the same category. The within-run coefficients of variation (CVs) were 3.0 similar to 15.4% and 5.2 similar to 23.5% for albumin and creatinine, respectively, showing good linearity. In interference tests, no interference was observed except for cases with high specific gravity. Conclusions: URiSuper-ACR showed good diagnostic performance for the detection of microalbuminuria and may be a useful screening test in clinical laboratories. (C) 2014 Wiley Periodicals, Inc.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE