Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation MethodsEvaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation Methods

Other Titles
Evaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation Methods
Authors
김주호최대섭김성후신화선서혜민최호철손승남태우석김삼수
Issue Date
2015
Publisher
대한자기공명의과학회
Keywords
Magnetic resonance imaging (MRI); Inversion time (TI); FreeSurfer; IBASPM
Citation
Investigative Magnetic Resonance Imaging, v.19, no.2, pp 67 - 75
Pages
9
Indexed
KCI
Journal Title
Investigative Magnetic Resonance Imaging
Volume
19
Number
2
Start Page
67
End Page
75
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/18103
DOI
10.13104/imri.2015.19.2.67
ISSN
2384-1095
2384-1109
Abstract
Purpose: To investigate the value of image post-processing software (FreeSurfer,IBASPM [individual brain atlases using statistical parametric mapping software])and inversion time (TI) in volumetric analyses of the hippocampus and to identifydifferences in comparison with manual tracing. Materials and Methods: Brain images from 12 normal adults were acquired usingmagnetization prepared rapid acquisition gradient echo (MPRAGE) with a slicethickness of 1.3 mm and TI of 800, 900, 1000, and 1100 ms. Hippocampal volumeswere measured using FreeSurfer, IBASPM and manual tracing. Statistical differenceswere examined using correlation analyses accounting for spatial interpretationspercent volume overlap and percent volume difference. Results: FreeSurfer revealed a maximum percent volume overlap and maximumpercent volume difference at TI = 800 ms (77.1 ± 2.9%) and TI = 1100 ms (13.1 ±2.1%), respectively. The respective values for IBASPM were TI = 1100 ms (55.3 ±9.1%) and TI = 800 ms (43.1 ± 10.7%). FreeSurfer presented a higher correlation thanIBASPM but it was not statistically significant. Conclusion: FreeSurfer performed better in volumetric determination than IBASPM. Given the subjective nature of manual tracing, automated image acquisition andanalysis image is accurate and preferable.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Dae Seob photo

Choi, Dae Seob
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE