Evaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation MethodsEvaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation Methods
- Other Titles
- Evaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation Methods
- Authors
- 김주호; 최대섭; 김성후; 신화선; 서혜민; 최호철; 손승남; 태우석; 김삼수
- Issue Date
- 2015
- Publisher
- 대한자기공명의과학회
- Keywords
- Magnetic resonance imaging (MRI); Inversion time (TI); FreeSurfer; IBASPM
- Citation
- Investigative Magnetic Resonance Imaging, v.19, no.2, pp 67 - 75
- Pages
- 9
- Indexed
- KCI
- Journal Title
- Investigative Magnetic Resonance Imaging
- Volume
- 19
- Number
- 2
- Start Page
- 67
- End Page
- 75
- URI
- https://scholarworks.gnu.ac.kr/handle/sw.gnu/18103
- DOI
- 10.13104/imri.2015.19.2.67
- ISSN
- 2384-1095
2384-1109
- Abstract
- Purpose: To investigate the value of image post-processing software (FreeSurfer,IBASPM [individual brain atlases using statistical parametric mapping software])and inversion time (TI) in volumetric analyses of the hippocampus and to identifydifferences in comparison with manual tracing.
Materials and Methods: Brain images from 12 normal adults were acquired usingmagnetization prepared rapid acquisition gradient echo (MPRAGE) with a slicethickness of 1.3 mm and TI of 800, 900, 1000, and 1100 ms. Hippocampal volumeswere measured using FreeSurfer, IBASPM and manual tracing. Statistical differenceswere examined using correlation analyses accounting for spatial interpretationspercent volume overlap and percent volume difference.
Results: FreeSurfer revealed a maximum percent volume overlap and maximumpercent volume difference at TI = 800 ms (77.1 ± 2.9%) and TI = 1100 ms (13.1 ±2.1%), respectively. The respective values for IBASPM were TI = 1100 ms (55.3 ±9.1%) and TI = 800 ms (43.1 ± 10.7%). FreeSurfer presented a higher correlation thanIBASPM but it was not statistically significant.
Conclusion: FreeSurfer performed better in volumetric determination than IBASPM.
Given the subjective nature of manual tracing, automated image acquisition andanalysis image is accurate and preferable.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > Department of Medicine > Journal Articles

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.