Detailed Information

Cited 13 time in webofscience Cited 13 time in scopus
Metadata Downloads

Fabrication of calix[4]arene-attached mesoporous ammonium molybdophosphate-silica hybrid and its application as an adsorbent for cesium ions

Authors
Ahn, JunhoLim, Na YoungPark, Jeong SuChoi, YeonweonJung, Jong Hwa
Issue Date
21-Apr-2017
Publisher
ROYAL SOC CHEMISTRY
Citation
NEW JOURNAL OF CHEMISTRY, v.41, no.8, pp 3196 - 3203
Pages
8
Indexed
SCI
SCIE
SCOPUS
Journal Title
NEW JOURNAL OF CHEMISTRY
Volume
41
Number
8
Start Page
3196
End Page
3203
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/13755
DOI
10.1039/c6nj03533g
ISSN
1144-0546
1369-9261
Abstract
The cesium cation is a common contaminant in medical and industrial products as well as in nuclear wastes, and it can present a serious risk to human health. Thus, the development of novel and facile methods for detection and elimination of cesium ions is important for environmental and biological systems. Mesoporous ammonium molybdophosphate-silica hybrid particles (AMP/Al-SiO2) were prepared, and the particles were immobilized on the calix[4]arene-based receptor 1 by a covalent bond between the carboxylic acid and amine, yielding the hybrid product AMP/Al-SiO2-1. In an evaluation of Cs+ adsorption on both particles, 57.8 mg g(-1) of Cs+ was adsorbed by AMP/Al-SiO2 while 72.2 mg g(-1) was adsorbed by AMP/Al-SiO2-1. The increased adsorption capacity of AMP/Al-SiO2-1 was due to a synergistic effect of the complex formation between 1 and Cs+ by a coordination bond. Additionally, the fluorescence intensity of AMP/Al-SiO2-1 was enhanced upon addition of Cs+. No significant fluorescence changes were observed in the parallel experiments with other metal ions such as Na+, K+, Mg2+, Rb+, Ca2+, Ba2+, Ag+, Ni2+, Zn2+ and Sr2+ ions. These findings confirmed that the AMP/Al-SiO2-1 can be useful as a chemoprobe for selective detection of Cs+ ions over a range of other metal ions in aqueous solution. We also determined that the fluorescence changes of AMP/Al-SiO2-1 were almost constant between pH 3 and 12. These results imply that the AMP/Al-SiO2-1 is applicable as a portable fluorogenic sensor for detection of Cs+ ions in environmental field studies.
Files in This Item
There are no files associated with this item.
Appears in
Collections
자연과학대학 > 화학과 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jung, Jong Hwa photo

Jung, Jong Hwa
자연과학대학 (화학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE