Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

A Study on Booster Pump System with Flow Sensor for Individual Flow Control Methodopen access

Authors
Rakibuzzaman, M.Kim, H. H.Kim, K. W.Suh, S. H.Bae, Y. S.
Issue Date
May-2022
Publisher
ISFAHAN UNIV TECHNOLOGY
Keywords
Keywords; Booster pump; Flow sensor; Computational fluid dynamics; Experiment; Energy consumption
Citation
JOURNAL OF APPLIED FLUID MECHANICS, v.15, no.3, pp.889 - 900
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF APPLIED FLUID MECHANICS
Volume
15
Number
3
Start Page
889
End Page
900
URI
https://scholarworks.bwise.kr/gnu/handle/sw.gnu/1321
DOI
10.47176/jafm.15.03.33153
ISSN
1735-3572
Abstract
Booster pump system (BPS) can control the number of revolutions through an inverter by combining two or more vertical or horizontal centrifugal pumps in a series. Efficiency and energy savings, the most appealing aspects of booster pump systems, can be improved by controlling the operating conditions of individual pumps by measuring the flow rate of each pump. For improved operation, a booster pump system with a flow sensor to detect individual pump flow rates and a control algorithm to manage each low and high flow rate pump???s revolutions per minute are critical. To achieve this, first, the turbine-type flow sensor was developed through computational fluid dynamics and experimentation. The flow sensor was improved using computational fluid dynamics, and its accuracy was validated through experiments. The resulting flow measurement accuracy of the designed flow sensor was within 4%, with a measurement uncertainty of 0.4%. In addition, an experimental pump facility was built and used to evaluate booster pump system performance to investigate the energy saving rate. Then, after driving one low-flow rate pump at a set pressure, the flow and frequency control operation algorithm was used. This algorithm increased the allowed output of the drive pump by increasing the inverter???s frequency. When the frequency corresponding to the allowed output is achieved in the low-flow rate pump rather than the high flow rate pump, power savings increased due to the low-flow rate pump???s extended drive range. The investigations on the developed system???s energy consumption revealed that the energy savings were approximately 6.2% compared to the conventional system, depending on the system in question. The development of a booster pump system with a flow sensor was tested, and it was found to be effective.
Files in This Item
There are no files associated with this item.
Appears in
Collections
융합기술공과대학 > 기계소재융합공학부 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyoung Ho photo

Kim, Hyoung Ho
융합기술공과대학 (기계소재융합공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE