Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Measurement of Uncertainty Using Standardized Protocol of Hand Grip Strength Measurement in Patients with SarcopeniaMeasurement of Uncertainty Using Standardized Protocol of Hand Grip Strength Measurement in Patients with Sarcopenia

Other Titles
Measurement of Uncertainty Using Standardized Protocol of Hand Grip Strength Measurement in Patients with Sarcopenia
Authors
하용찬유준일박영진이창한박기수
Issue Date
2018
Publisher
대한골대사학회
Keywords
Hand; Hand strength; Sarcopenia; Uncertainty
Citation
대한골대사학회지, v.25, no.4, pp 243 - 249
Pages
7
Indexed
SCOPUS
KCI
Journal Title
대한골대사학회지
Volume
25
Number
4
Start Page
243
End Page
249
URI
https://scholarworks.gnu.ac.kr/handle/sw.gnu/12453
ISSN
2287-6375
2287-7029
Abstract
Background: The aim of this study was to determine the accuracy and error range of hand grip strength measurement using various methods. Methods: Methods used for measurement of hand grip strength in 34 epidemiologic studies on sarcopenia were analyzed. Maximum grip strength was measured in a sitting position with the elbow flexed at 90 degrees, the shoulder in 0 degrees flexion, and the wrist in neutral position (0 degrees). Maximum grip strength in standing position was measured with the shoulder in 180 degrees flexion, the elbow fully extended, and the wrist in neutral position (0 degrees). Three measurements were taken on each side at 30 sec intervals. The uncertainty of measurement was calculated. Results: The combined uncertainty in sitting position on the right and left sides was 1.14% and 0.38%, respectively, and the combined uncertainty in standing position on the right and left sides was 0.35 and 1.20, respectively. The expanded uncertainty in sitting position on the right and left sides was 2.28 and 0.79, respectively, and the expanded uncertainty in standing position on the right and left sides was 0.71 and 2.41, respectively (k=2). Conclusions: Uncertainty of hand grip strength measurement was identified in this study, and a significant difference was observed between measurement. For more precise diagnosis of sarcopenia, dynamometers need to be corrected to overcome uncertainty.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Ki Soo photo

Park, Ki Soo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE