Cited 0 time in
BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가-
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박성철 | - |
| dc.contributor.author | 하주완 | - |
| dc.contributor.author | 김환용 | - |
| dc.contributor.author | 송영학 | - |
| dc.date.accessioned | 2022-12-26T17:33:05Z | - |
| dc.date.available | 2022-12-26T17:33:05Z | - |
| dc.date.issued | 2018 | - |
| dc.identifier.issn | 1976-6483 | - |
| dc.identifier.issn | 2586-0666 | - |
| dc.identifier.uri | https://scholarworks.gnu.ac.kr/handle/sw.gnu/12396 | - |
| dc.description.abstract | Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics. | - |
| dc.format.extent | 11 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가- | - |
| dc.title.alternative | An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.22696/jkiaebs.20180055 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.12, no.6, pp 669 - 679 | - |
| dc.citation.title | 한국건축친환경설비학회 논문집 | - |
| dc.citation.volume | 12 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 669 | - |
| dc.citation.endPage | 679 | - |
| dc.identifier.kciid | ART002419241 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | BEMS (BuildingEnergyManagementSystem) | - |
| dc.subject.keywordAuthor | Measured Data | - |
| dc.subject.keywordAuthor | Geothermal System | - |
| dc.subject.keywordAuthor | Heat Storage System | - |
| dc.subject.keywordAuthor | Operation Status Analysis | - |
| dc.subject.keywordAuthor | BEMS | - |
| dc.subject.keywordAuthor | 실측데이터 | - |
| dc.subject.keywordAuthor | 지열시스템 | - |
| dc.subject.keywordAuthor | 축열시스템 | - |
| dc.subject.keywordAuthor | 운전현황 분석 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Gyeongsang National University Central Library, 501, Jinju-daero, Jinju-si, Gyeongsangnam-do, 52828, Republic of Korea+82-55-772-0532
COPYRIGHT 2022 GYEONGSANG NATIONAL UNIVERSITY LIBRARY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.