BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가-

Full metadata record
DC Field Value Language
dc.contributor.author박성철-
dc.contributor.author하주완-
dc.contributor.author김환용-
dc.contributor.author송영학-
dc.date.accessioned2022-12-26T17:33:05Z-
dc.date.available2022-12-26T17:33:05Z-
dc.date.issued2018-
dc.identifier.issn1976-6483-
dc.identifier.issn2586-0666-
dc.identifier.urihttps://scholarworks.gnu.ac.kr/handle/sw.gnu/12396-
dc.description.abstractEnergy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.-
dc.format.extent11-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국건축친환경설비학회-
dc.titleBEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가--
dc.title.alternativeAn Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.22696/jkiaebs.20180055-
dc.identifier.bibliographicCitation한국건축친환경설비학회 논문집, v.12, no.6, pp 669 - 679-
dc.citation.title한국건축친환경설비학회 논문집-
dc.citation.volume12-
dc.citation.number6-
dc.citation.startPage669-
dc.citation.endPage679-
dc.identifier.kciidART002419241-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorBEMS (BuildingEnergyManagementSystem)-
dc.subject.keywordAuthorMeasured Data-
dc.subject.keywordAuthorGeothermal System-
dc.subject.keywordAuthorHeat Storage System-
dc.subject.keywordAuthorOperation Status Analysis-
dc.subject.keywordAuthorBEMS-
dc.subject.keywordAuthor실측데이터-
dc.subject.keywordAuthor지열시스템-
dc.subject.keywordAuthor축열시스템-
dc.subject.keywordAuthor운전현황 분석-
Files in This Item
There are no files associated with this item.
Appears in
Collections
공과대학 > School of Architectural Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Young Hak photo

Song, Young Hak
공과대학 (건축공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE