FSE T2-weighted two-point Dixon technique for fat suppression in the lumbar spine: comparison with SPAIR techniqueopen access
- Authors
- Lee, Sangmin; Choi, Dae Seob; Shin, Hwa Seon; Baek, Hye Jin; Choi, Ho Cheol; Park, Sung Eun
- Issue Date
- May-2018
- Publisher
- AVES
- Citation
- DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, v.24, no.3, pp.175 - 180
- Indexed
- SCIE
SCOPUS
- Journal Title
- DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
- Volume
- 24
- Number
- 3
- Start Page
- 175
- End Page
- 180
- URI
- https://scholarworks.bwise.kr/gnu/handle/sw.gnu/11685
- DOI
- 10.5152/dir.2018.17320
- ISSN
- 1305-3825
- Abstract
- PURPOSE Fat suppression magnetic resonance imaging (MRI) technique has been used to improve the diagnostic confidence in lumbar spine diseases. We aimed to compare T2-weighted water-fat separation technique (T2 Dixon) with spectral attenuated inversion recovery (SPAIR) image for fat suppression. METHODS Lumbar spine MRI examinations were per formed in 79 patients by using a 3.0 T machine. We compared T2 Dixon water-only image and SPAIR image for the evaluation of fat suppression quality and lesion conspicuity. For qualitative evaluation, two radiologists scored the images from Dixon and SPAIR for fat suppression uniformity and lesion conspicuity. Quantitative assessment was also performed for 39 lesions in 26 patients who had lesions in their spine bodies. Contrast ratio (CR) and contrast-to-noise ratio (CNR) were calculated by signal intensity measurement of the lesions, adjacent bodies, and background noise.The Wilcoxon's signed-rank test and paired sample t-test were used to assess the statistical significance of qualitative and quantitative data, respectively. RESULTS For qualitative assessment, T2 Dixon water-only image showed higher mean scores for fat suppression quality and lesion conspicuity than SPAIR (2.99 +/- 0.11 vs. 2.18 +/- 0.38 and 2.84 +/- 0.37 vs. 2.28 +/- 0.51, respectively). For quantitative measurement, the CR and CNR values of the lesions were higher on T2 Dixon than on SPAIR. Both qualitative and quantitative results showed statistically significant differences between T2 Dixon and SPAIR (P < 0.01 in all). CONCLUSION T2 Dixon sequence was superior to SPAIR for the quality of fat suppression and for the delineation of lumbar spine lesions.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > Department of Medicine > Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.