Detailed Information

Cited 17 time in webofscience Cited 20 time in scopus
Metadata Downloads

FSE T2-weighted two-point Dixon technique for fat suppression in the lumbar spine: comparison with SPAIR techniqueopen access

Authors
Lee, SangminChoi, Dae SeobShin, Hwa SeonBaek, Hye JinChoi, Ho CheolPark, Sung Eun
Issue Date
May-2018
Publisher
AVES
Citation
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, v.24, no.3, pp.175 - 180
Indexed
SCIE
SCOPUS
Journal Title
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Volume
24
Number
3
Start Page
175
End Page
180
URI
https://scholarworks.bwise.kr/gnu/handle/sw.gnu/11685
DOI
10.5152/dir.2018.17320
ISSN
1305-3825
Abstract
PURPOSE Fat suppression magnetic resonance imaging (MRI) technique has been used to improve the diagnostic confidence in lumbar spine diseases. We aimed to compare T2-weighted water-fat separation technique (T2 Dixon) with spectral attenuated inversion recovery (SPAIR) image for fat suppression. METHODS Lumbar spine MRI examinations were per formed in 79 patients by using a 3.0 T machine. We compared T2 Dixon water-only image and SPAIR image for the evaluation of fat suppression quality and lesion conspicuity. For qualitative evaluation, two radiologists scored the images from Dixon and SPAIR for fat suppression uniformity and lesion conspicuity. Quantitative assessment was also performed for 39 lesions in 26 patients who had lesions in their spine bodies. Contrast ratio (CR) and contrast-to-noise ratio (CNR) were calculated by signal intensity measurement of the lesions, adjacent bodies, and background noise.The Wilcoxon's signed-rank test and paired sample t-test were used to assess the statistical significance of qualitative and quantitative data, respectively. RESULTS For qualitative assessment, T2 Dixon water-only image showed higher mean scores for fat suppression quality and lesion conspicuity than SPAIR (2.99 +/- 0.11 vs. 2.18 +/- 0.38 and 2.84 +/- 0.37 vs. 2.28 +/- 0.51, respectively). For quantitative measurement, the CR and CNR values of the lesions were higher on T2 Dixon than on SPAIR. Both qualitative and quantitative results showed statistically significant differences between T2 Dixon and SPAIR (P < 0.01 in all). CONCLUSION T2 Dixon sequence was superior to SPAIR for the quality of fat suppression and for the delineation of lumbar spine lesions.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medicine > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Dae Seob photo

Choi, Dae Seob
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE