상세 보기
이중창호 시스템이 적용된 주상복합건물의 실내 기류특징 분석
- 정창헌;
- 김태연;
- 이승복;
- 황석호
초록
The purpose of this study is to evaluate the ventilation performance of Double Window System in the mixed-use apartment by CFD simulation. The average indoor air speed and PMV are the performance indicators of the study. Indoor air speed and PMV of target building is determined and compared in each case of double window and single window. According to the preliminary analysis of the air flow transmission through each window system in the pressure difference of 10 Pa, double window system shows the larger range of airflow than the conventional project type window system. When the double window system implemented to the mixed-use apartment, indoor air speed increased to 127% in the maximum ventilation mode. In minimum ventilation mode, indoor air speed is 67% of project window system. In the respect of thermal comfort, PMV slightly reduced by 0 ~ 0.2 with the increased air flow speed by the application of double window system. These results indicate the restricted usefulness of the double window system in the respect of the occupants’ thermal perception.
키워드
- 제목
- 이중창호 시스템이 적용된 주상복합건물의 실내 기류특징 분석
- 제목 (타언어)
- Indoor Air Flow Pattern in the Mixed-Use Apartment with Double Window System
- 저자
- 정창헌; 김태연; 이승복; 황석호
- 발행일
- 2013
- 저널명
- 대한건축학회논문집
- 권
- 29
- 호
- 12
- 페이지
- 287 ~ 296