Tri-axial shaking table testing of lighting support systems with pulley friction dampers and integrated dummy masses
  • Han, Tran-Van
  • Kim, Sung Chan
  • Shin, Jiuk
  • Cuong, Nguyen Huu
  • Lee, Kihak
Citations

WEB OF SCIENCE

2
Citations

SCOPUS

3

초록

Investigating pulley wireway systems equipped with friction dampers as alternatives to traditional exposed raceway light fixtures, this study adheres to the ICC-ES AC156 standard and evaluates the impact of system mass and connector types on seismic behavior using shaking table tests. The key findings indicate that an increased system mass variably affects the fundamental frequency of the system, depending on the type of connectors. In terms of earthquake performance, direct connectors outperformed pole connectors in the original system configuration, and the addition of dummy masses significantly reduced seismic energy while stabilizing acceleration responses in pole connector systems. Moreover, the study underscores the critical importance of minimizing pole length in systems using pole connectors and adopting a lower mounting height in systems with direct connectors to improve seismic performance. © 2023 The Authors

키워드

Dummy massesFriction damperSeismic performanceShaking table testingVibration attenuationWireway vibration attenuation systemNONSTRUCTURAL COMPONENTSSEISMIC RESPONSEPERFORMANCEEARTHQUAKEEQUIPMENTFRAGILITYCABINETSPECTRADESIGNSTATE
제목
Tri-axial shaking table testing of lighting support systems with pulley friction dampers and integrated dummy masses
저자
Han, Tran-VanKim, Sung ChanShin, JiukCuong, Nguyen HuuLee, Kihak
DOI
10.1016/j.rineng.2023.101706
발행일
2024-03
유형
Article
저널명
Results in Engineering