유동소음기용 다공성 발포알루미늄에 대한 유동해석

CFD Analysis of Porous Foamed Aluminium for Flow Silencer
  • 김나용
  • 김봉환

초록

There are many disadvantages to existing silencers used in power plants. Recently, high-performance silencers are required in society, so it is necessary to develop silencers accordingly. Therefore, in this study, to develop the flow silencer by taking advantage of the foamed aluminum, the property values such as loss coefficient and porosity were obtained through experiments, based on the Forchheimer's law. CFD analysis was performed by applying a porous modeling technique to foamed aluminum and the results were compared with experimental values. The error rate between the results of the experiment and the flow analysis is within about 2.79%, so the results of the experiment and the analysis agree relatively well. When the foamed aluminum was installed, the flow noise was reduced by about 5.14dB.

키워드

Flow silencerFoamed aluminiumPorosityPorous mediaLoss coefficientQuadratic resistance coefficientPressure dropCFD유동소음기발포알루미늄다공도다공성 매질손실계수2차 저항계수압력강하전산유체역학
제목
유동소음기용 다공성 발포알루미늄에 대한 유동해석
제목 (타언어)
CFD Analysis of Porous Foamed Aluminium for Flow Silencer
저자
김나용김봉환
DOI
10.17958/ksmt.22.5.202010.845
발행일
2020
저널명
한국기계기술학회지
22
5
페이지
845 ~ 851