There are many disadvantages to existing silencers used in power plants. Recently, high-performance silencers are required in society, so it is necessary to develop silencers accordingly. Therefore, in this study, to develop the flow silencer by taking advantage of the foamed aluminum, the property values such as loss coefficient and porosity were obtained through experiments, based on the Forchheimer's law. CFD analysis was performed by applying a porous modeling technique to foamed aluminum and the results were compared with experimental values. The error rate between the results of the experiment and the flow analysis is within about 2.79%, so the results of the experiment and the analysis agree relatively well. When the foamed aluminum was installed, the flow noise was reduced by about 5.14dB.
키워드
- 제목
- 유동소음기용 다공성 발포알루미늄에 대한 유동해석
- 제목 (타언어)
- CFD Analysis of Porous Foamed Aluminium for Flow Silencer
- 저자
- 김나용; 김봉환
- 발행일
- 2020
- 저널명
- 한국기계기술학회지
- 권
- 22
- 호
- 5
- 페이지
- 845 ~ 851