상세 보기
대규모 산업공정에서 배출되는 비산먼지의 특성
- 정재우;
- 이용환;
- 이현돈;
- 박정호;
- 전기일;
- 외 1명
초록
The physical, chemical and electrical properties of fly ashes emitted from large scale industrial processes such as thermoelectric power plant (P.P.), sinter process (S.P.), cement industry (C.I.), combined heat power plant (C.P.), and municipal waste incinerator (I.P.) were investigated. The major compounds of dust samples exhausted from P.P., S.P. and C.I. were SiO2 (& Al2O3), Fe2O3, and SiO2 (& CaO), respectively. the major component of dust emitted from I.P. was CaO, due to the injection of Ca(OH)2 for the acidic gas treatment. The dust density was mainly related to the composition of samples, and proportional to the amount of inorganic contents. Because dust samples were collected from the precipitated dusts in the particle collection devices, the content of coarse particles was much higher than that of fine particles. The unburned residues were mainly composed of sulfur and organic carbon. The dust resistivity was significantly affected by the dust composition.
키워드
- 제목
- 대규모 산업공정에서 배출되는 비산먼지의 특성
- 제목 (타언어)
- Characteristics of Fly Ashes Emitted from Large Scale Industrial Process
- 저자
- 정재우; 이용환; 이현돈; 박정호; 전기일; 조무현
- 발행일
- 2003
- 저널명
- 한국폐기물자원순환학회지
- 권
- 20
- 호
- 2
- 페이지
- 179 ~ 185
- 출판사
- 한국폐기물자원순환학회
- 발행국가
- 대한민국
- 분량
- 7 페이지
- ISSN
- E 2287-5638
P 2093-2332