권상 작업 중 슬링 파손으로 인한 블록 지상 낙하 충격에 대한 준정적 해석

Quasi-Static Analysis of Block Impact Against the Ground Due to Sling Failure During Block Lifting

초록

Recently, shipyards are making many efforts to reduce the number of the mounted blocks by increasing the block size. This is to improve productivity and reduce related costs by minimizing block movement and shortening the building period. However, as the blocks become larger, the weight increases considerably. If the target block has a damage due to an unexpected accident during block lifting, it may seriously cause a problem of the reusability of the block. In this study, a large-sized block of the offshore structure weighing 480 tons was lifting with a total of seven sling belts, and one sling belt was broken while it was moving, resulting in a situation in which a part of the edge of the block collided with the ground. The aim of this paper is to verify the structural integrity of the block that directly collides with the ground in the form of free fall due to the sling breakage. Considering that the hook loads acting on several sling belts holding the block are redistributed when a sling belt is broken, the hook loads were recalculated at the angle just before the sling breakage. These loads were used to check the safety of the sling belts. In addition, FE analysis was performed by calculating the amount of impact from the free fall condition, obtaining the impact area by using Hertz's contact theory, and then applying the impact load to the area.

키워드

블록권상권상고리슬링 파손블록 손상후크 하중구조 건전성Block liftingLifting lugSling failureBlock damageHook loadStructural integrity
제목
권상 작업 중 슬링 파손으로 인한 블록 지상 낙하 충격에 대한 준정적 해석
제목 (타언어)
Quasi-Static Analysis of Block Impact Against the Ground Due to Sling Failure During Block Lifting
저자
김선엽이탁기윤정호
DOI
10.3744/SNAK.2021.58.2.084
발행일
2021
저널명
대한조선학회 논문집
58
2
페이지
84 ~ 89