악취 배출구의 합리적인 배출규제를 위한 사례연구

A Case Study for Reasonable Emission Regulation of Odor Exhaust Stack

초록

In this study, field experiment, odor simulator, and dispersion modeling were used to evaluate the odor impact from J sewage sludge treatment facility. The height and flow rate of exhaust stack at this facility were 22.3 m and 100 Nm3/min. The mean odor concentrations of the wet scrubber inlet and exhaust stack were 267±160 and 93±44 OU/m3, respectively. The odor removal efficiency of wet scrubber showed 65%. The odor simulator is used for the regulated standard calculation of the exhaust pipe(stack). Resulting odor emission rate(OER) by odor simulator was 2.4×106(24,000 OU/m3). The forecasting result by Screen3 modeling showed that odor exhaust concentration up to 30,000 OU/m3 was’t exceeded maximum allowable emission level on site boundary(15 OU/m3).

키워드

Odor exhaust stack; Emission regulation; Odor simulator; Screen3 model
제목
악취 배출구의 합리적인 배출규제를 위한 사례연구
제목 (타언어)
A Case Study for Reasonable Emission Regulation of Odor Exhaust Stack
저자
박정호; 이형천
DOI
10.5322/JESI.2016.25.1.155
발행일
2016
저널명
한국환경과학회지
권
25
호
1
페이지
155 ~ 161