상세 보기
8kW급 디젤발전기 소음기 내부 유동에 관한 수치해석
Numerical analysis of the Internal Flow of 8kW Grade Diesel Generator Muffler
- 이중섭;
- 이태의;
- 이치우
초록
From the flow analysis of the silencer for 8 kW diesel generators, the following results were obtained. For silencer-1, it was confirmed that the holes formed at the inlet-side portion connect into the exhaust pipe in the chamber. The exhaust pipe installed inside silencer-1 was integrally connected through the holes in the chamber. As a result, it was confirmed that the pressure inside the chamber was kept stable. It was confirmed that the pressure loss generated inside an absorptive type silencer such as silencer-2 was small. The differential pressure of the inlet-outlet of silencer-1 and silencer-2 was confirmed to be 494 Pa at 15 m/s, 859 Pa at 20 m/s, 1326 Pa at 25 m/s, and 1911 Pa at 30 m/s.
키워드
Diesel Generator(디젤발전기); Muffler(소음기); Numerical Analysis(수치해석)
- 제목
- 8kW급 디젤발전기 소음기 내부 유동에 관한 수치해석
- 제목 (타언어)
- Numerical analysis of the Internal Flow of 8kW Grade Diesel Generator Muffler
- 저자
- 이중섭; 이태의; 이치우
- 발행일
- 2018
- 저널명
- 한국기계가공학회지
- 권
- 17
- 호
- 3
- 페이지
- 45 ~ 50
- 언어
- KOR
- 출판사
- 한국기계가공학회
- 발행국가
- 대한민국
- 분량
- 6 페이지
- ISSN
- E 2288-0771
P 1598-6721