진주시 대기중 PM10 및 PM2.5의 질량농도 특성

Characterization of PM10 and PM2.5 Mass Concentrations in Jinju

초록

Ambient particulate matters(PM10 and PM2.5) were investigated at GNTECH university in Jinju city. Samples were collected using a dichotomous sampler(series 240, Andersen Corp.) and a TEOM(Tapered Element Oscillating Microbalance) monitor period from November 2012 to October 2013. For the dichotomous sampler measurements, daily 24-h integrated PM2.5 and PM10–2.5 ambient air samples were collected at a total flow rate of 16.7 L /min. For the TEOM monitor measurements, daily 1-h integrated PM10 ambient air samples were collected at a flow rate of 16.7 L /min. The annual average concentrations of PM10-2.5 and PM2.5 by a dichotomous sampler were 10.0±6.1 μg/m3 and 22.6±9.3 μg/m3, respectively. And PM10 concentration by dichotomous sampler were similar to TEOM monitor by 32.7±12.9 μg/m3 and 31.7±11.3 μg/m3, respectively. And good correlation (R2=0.964) between the two methods was observed. The annual average of PM2.5/PM10 ratio was 0.70±0.12.

키워드

Ambient aerosolPM10PM2.5Mass concentrationJinju city
제목
진주시 대기중 PM10 및 PM2.5의 질량농도 특성
제목 (타언어)
Characterization of PM10 and PM2.5 Mass Concentrations in Jinju
저자
박정호박기형서정민
DOI
10.5322/JESI.2014.23.12.1963
발행일
2014
저널명
한국환경과학회지
23
12
페이지
1963 ~ 1970