다중이용시설 및 학교 교사내 실내공기중 섬유상 입자의 농도 특성

Characterizations of Airborne Fiber Particle Concentrations in Public Facilities and Schools

초록

his study was investigated the characteristics of indoor air concentration of fiber particles in 30 public facilities and 245 schools by PCM (phase contrast microscopy). Also SEM/EDX (scanning electron microscope / energy dispersive using X-ray analysis) was used to obtain physicochemical information of asbestos fiber and to classify asbestos and non-asbestos of fiber particles. The airborne concentrations of fiber particles were 0.0009±0.0009 counts/mL in public facilities and 0.0012±0.0006 counts/mL in schools by PCM. All the samples were satisfied with the IAQ (indoor air quality) level of 0.01counts/mL. In classification of 4 type shapes, over 80% of the fiber particles were identified as single fiber type. And this study analysed airborne fiber particles in 4 sites for identifying asbestos of by SEM/EDX. The asbestos fibers in most samples could not be found.

키워드

Indoor air; Fiber particle; Asbestos; PCM; SEM/EDX