Performance evaluation of RC beam-column joints with different bonding interfaces

Citations

WEB OF SCIENCE

7
Citations

SCOPUS

8

초록

Reinforced Concrete (RC) structures located on ocean coasts are damaged by salt water, leading to concrete deterioration. Due to this deterioration of the concrete, the metal rebar inside starts to corrode, because there is no longer concrete around it to prevent exposure to the outside environment. Such corrosion causes serious degradation of the cohesion between the steel and the concrete, and the performance capacity of the bonding between concrete and rebar. In this study, the performance of RC beam-column joints was evaluated. The interface between concrete and reinforcing bars in the RC beam-column joint specimens was partially un-bonded to simulate corrosion. The mechanical behavior and energy dissipation capacity of un-bonded RC beam-column joints were evaluated by experiment. Numerical studies were also performed with the help of finite element methods. Results from the experimental tests and numerical studies of RC beam-column joints at bonded and un-bonded interfaces between concrete and reinforcing bars are compared and discussed in terms of energy dissipation capacity, strength, and crack distribution. (C) 2018 Sharif University of Technology. All rights reserved.

키워드

RC beam-column joint; Non-linear analysis; Un-bonded rebar; Seismic performance; CONCRETE; RESISTANCE; MODEL; SLIP
제목
Performance evaluation of RC beam-column joints with different bonding interfaces
저자
Jung, W.; Kim, J.; Kwon, M.
DOI
10.24200/sci.2017.4175
발행일
2018-01
유형
Article
저널명
Scientia Iranica
권
25
호
1
페이지
11 ~ 21