상세 보기
Long-term results from cyclocryotherapy applied to the 3o'clock and 9o'clock positions in blind refractory glaucoma patients
- Kim, B.S.;
- Kim, Y.J.;
- Seo, S.W.;
- Yoo, J.M.;
- Kim, S.J.
SCOPUS
13초록
PURPOSE: To report the long-term follow-up results after cyclocryotherapy, applied to the 3-o'clock and 9-o'clock positions in blind refractory glaucoma patients.METHODS: We retrospectively reviewed the charts of 19 blind patients, and a total of 20 eyes with refractory glaucoma who were treated with cyclocryotherapy. Cyclocryotherapy treatments were performed using a retinal cryoprobe. The temperature of each cyclocryotherapy spot was -80°C and each spot was maintained in place for 60 seconds. Six cyclocryotherapy spots were placed in each quadrant, including the 3-o'clock and 9-o'clock positions.RESULTS: The mean baseline pretreatment intraocular pressure (IOP) in all eyes was 50.9 ± 12.5 mmHg, which significantly decreased to a mean IOP at last follow-up of 14.1 ± 7.1 mmHg (p < 0.001). The mean number of antiglaucoma medications that patients were still taking at last follow-up was 0.3 ± 0.6. Devastating post-procedure phthisis occurred in only one eye.CONCLUSIONS: Cyclocryotherapy, performed at each quadrant and at the 3-o'clock and 9-o'clock position, is an effective way to lower IOP and, thus, is a reasonable treatment option for refractory glaucoma patients who experience with ocular pain and headaches.
키워드
- 제목
- Long-term results from cyclocryotherapy applied to the 3o'clock and 9o'clock positions in blind refractory glaucoma patients
- 저자
- Kim, B.S.; Kim, Y.J.; Seo, S.W.; Yoo, J.M.; Kim, S.J.
- 발행일
- 2015
- 유형
- Article
- 권
- 29
- 호
- 1
- 페이지
- 47 ~ 52
- 언어
- ENG
- 발행국가
- 대한민국
- 분량
- 6 페이지
- ISSN
- E 2092-9382
P 1011-8942