상수도용 계량 밸브 임펠러 회전수에 따른 유동해석에 관한 연구

A Study on the Flow Analysis According to Impeller Speed for City Water Supply Measuring Valve

초록

This study conducts the flow analysis on the basis of the impeller RPM of water metering valve. The software used for the flow analysis is STAR-CCM+. In terms of the structure of the metering valve, it has an impeller installed inside, and a metering chamber has inlet and outlet holes. The flow analysis on the water metering valve drew the following conclusions: Regarding the flow field in the valve, the impeller had the highest velocity distribution, and complex flow field was generated in the metering chamber. In particular, since the path between the inlet and outlet holes in the metering chamber and the valve body was narrow, there was a section that had flow field interference. The flow rate and flow coefficient distribution according to the impeller RPM were on the linear increase. Given that, it showed the feature of the valve used for water metering on the basis of the impeller RPM.

키워드

High-Pressure Drop Control ValveValve Flow CoefficientThermal Stress AnalysisFlow Analysis
제목
상수도용 계량 밸브 임펠러 회전수에 따른 유동해석에 관한 연구
제목 (타언어)
A Study on the Flow Analysis According to Impeller Speed for City Water Supply Measuring Valve
저자
김태준이중섭이치우
발행일
2023-04
저널명
한국산업융합학회논문집
26
2
페이지
307 ~ 313