상세 보기
소규모 복도-더그매 예열 음압환기방식 무창자돈사의 최적 환기 요건에 관한 연구
- 이승주;
- 장동일;
- 황선호;
- Winson M. Gutierrez;
- 장홍희
초록
This study was carried out to determine necessary conditions for optimal ventilation of small windowless piglet house (4.0 (W) × 11.0 (L) × 2.6(H) m) with corridor and attic for preheating using CFD (Computational Fluid Dynamics)simulation. The experimental weaning piglet house was consisted of a corridor, an attic, 4 rooms (3.0 (W) × 2.75(L) m),3 fences (0.7(H) m), 5 air inlets and 2 exhaust fans (0.4 (D) m) and simulated using CFD code, FLUENT. The simulation results for the experimental weaning piglet house showed that each room was uniformly ventilated under all the experimental conditions and air velocities at 0.1 m above floor are less than 0.15 m/s for 0.75 m/s and 1.0 m/s of air inlet velocity but 0.61 m/s for 1.25 m/s. The simulation results are similar to the measured results. Considering the air flow pattern, ventilating efficiency, air velocity at 0.1 m above floor and cold stress of weaning piglets and so on, the optimum velocity of air inlet might be 1.0 m/s.
키워드
- 제목
- 소규모 복도-더그매 예열 음압환기방식 무창자돈사의 최적 환기 요건에 관한 연구
- 제목 (타언어)
- Necessary Conditions for Optimal Ventilation of Small Negative Pressure Ventilating Piglet House with Corridor and Attic for Preheating
- 저자
- 이승주; 장동일; 황선호; Winson M. Gutierrez; 장홍희
- 발행일
- 2010
- 권
- 35
- 호
- 6
- 페이지
- 434 ~ 442
- 언어
- KOR
- 출판사
- 한국농업기계학회
- 발행국가
- 대한민국
- 분량
- 9 페이지
- ISSN
- E 2234-1862
P 1738-1266