충격 감쇄용 신축이음관의 상수도 배관 적용을 위한 구조 안정성 해석

Analysis on Structural Stability for Applying Flexible Joint with Impact Damping to Pipe for Water Supply

초록

The pipe for water supply is essential part among SOC (Social Overhead Capital) fields. Pipe for water supply is mainly damaged by deterioration of pipe, earthquake, ground sinking and so on. The leakage of water have been led to enormous economical loss in our country. The purpose of this study was to investigate the structural stability of flexible joint for relaxing impact due to earthquake and ground sinking. For this purpose, flexible joint was simulated using tensile load and internal pressure. As the results, flexible joint for structural stability was needed the tensile load of below 3 ton and internal pressure of below 60 kgf/cm2. However, it is considered that real flexible joint should be applied more high safety factor than that of simulation result because of combined stress.

키워드

Flexible joint(신축이음관); Impact damping(충격감쇄); Pipe for water supply(상수도 배관); Leakage of water(누수); Structural stability(구조 안전성); SOC(사회간접자본)
제목
충격 감쇄용 신축이음관의 상수도 배관 적용을 위한 구조 안정성 해석
제목 (타언어)
Analysis on Structural Stability for Applying Flexible Joint with Impact Damping to Pipe for Water Supply
저자
서석진; 양영준
DOI
10.17958/ksmt.21.5.201910.818
발행일
2019
저널명
한국기계기술학회지
권
21
호
5
페이지
818 ~ 825