Breakup of a leaky dielectric drop in a uniform electric field

  • Dong, Qingming
  • Sau, Amalendu
Citations

WEB OF SCIENCE

37
Citations

SCOPUS

37

초록

Electrohydrodynamic (EHD) breakup phenomena for a leaky dielectric drop suspended in another immiscible viscous dielectric and subjected to a uniform electric field are examined using the leaky dielectric theory and the explicit forcing lattice Boltzmann method, by taking into account full nonlinear inertia effects. The breakup modes are first computed for varied conductivity of the drop fluid, as the viscosity ratio lambda (=mu(in)/mu(out)) is momentarily set to unity, that is, for the slightly conducting (R = sigma(in)/sigma(out) < 10), moderately conducting (10 <= R <= 20), and highly conducting (R > 20) cases. For slightly conducting drops (R = 5) only one breakup mode via two symmetrical necks persists for permittivity ratios 0.05 < Q =epsilon(in)/epsilon(out) < 3.0 and electric capillary number Ca-E > Ca-E,(critical) (ratio of electric and surface tension forces), despite significant length-scale variation of mother and daughter drops. At higher Q (for increased drop permittivity) two necks move closer to the bulbous midpart of the extended droplet, which helps enlarge two daughter drops. However, in the case of moderately conducting drops (10 <= R <= 20) the number of necks increased to four for increased Ca-E. Accordingly two pairs of symmetrical daughter drops are created because of recurrent fluctuations of the electrical shear stress and centerline momentum flux. For highly conducting cases of R > 20, depending on Ca-E, three distinctly elongated droplet states are formed prior to breakup, which results in the onset of three different breakup modes, namely, via formations of lobed ends (Ca-E <= 0.264), pointed ends (Ca-E <= 0.68), and nonpointed ends (Ca-E > 0.83). While being consistent with past measurements, here we precisely characterize the associated breakup mechanisms and physics in terms of the interactive electric pressure, electric shear stress, and hydrodynamic pressure plus velocity gradients. Since the EHD drop breakup is a dynamic process, on an elongated slender drop the activated locally distinct driving forces, i.e., electric pressure at the end regions and tangential electric stress in the midsection, effectively lead to neck formations by virtue of the created high centerline velocity gradient. Accordingly, resulting variations of local extension rate and net mass flux toward drop ends or into intermediate bulbous regions facilitate the multiple-mode drop breakup via the inertia effect, whereas the developed negative curvature around a neck encourages capillary breakup. We also explicitly reveal the effect of the viscosity contrast lambda, which particularly influences the breakup characteristics over a broader range of conductivity ratios.

키워드

LATTICE BOLTZMANN SIMULATIONELECTROHYDRODYNAMIC DEFORMATIONIMMISCIBLE DROPLETCONDUCTING DROPCHARGED DROPSFLUIDELECTROROTATIONDISPLACEMENTSTABILITYSTEADY
제목
Breakup of a leaky dielectric drop in a uniform electric field
저자
Dong, QingmingSau, Amalendu
DOI
10.1103/PhysRevE.99.043106
발행일
2019-04-18
유형
Article
저널명
Physical Review e
99
4