Numerical analysis on the hygrothermal behavior of building envelope according to CLT wall assembly considering the hygrothermal-environmental zone in Korea

Citations

WEB OF SCIENCE

16
Citations

SCOPUS

17

초록

As buildings generally have become larger and more airtight, the ventilation rate has decreased further, causing insufficient ventilation which leads to moisture problems such as condensation, mold growth, reduction of thermal insulation performance and corrosion of building materials. In order to prevent moisture problems, it is essential to understand the thermal and hygric status of a climatic region. In this study, the hygrothermal environmental zone considering not only the thermal environment but also the hygric environment was derived by analyzing the climate environment in Korea. The hygrothermal environmental zone has the advantage of being able to take into account the hygrothermal environment of the unexplored regions and to cope with climate change by quantifying the thermal and hygric environmental indexes in each region. Finally, the long-term moisture risk of the building envelopes was evaluated. As the results, it is considered that the proposed hygrothermal environmental zone is appropriate and it is necessary to consider the hygric environment in order to secure the moisture stability of the building envelope.

키워드

Regional classificationHygrothermal environmental zoneCross-laminated timber houseMoisture problemEnergy performanceMOLD GROWTHMOISTUREPERFORMANCEINSULATION
제목
Numerical analysis on the hygrothermal behavior of building envelope according to CLT wall assembly considering the hygrothermal-environmental zone in Korea
저자
Chang, Seong JinYoo, JiwonWi, SeunghwanKim, Sumin
DOI
10.1016/j.envres.2020.110198
발행일
2020-12
유형
Article
저널명
Environmental Research
191