Real Scale Test Rotor를 이용한 3점지지 밸런싱에 관한 연구

Study on Three-point Support Balancing using Real Scale Test Rotor
  • 박성훈
  • 손민아
  • 박동희
  • 최병근

초록

This study uses a secondary liquified natural gas (LNG) high-pressure pump with a large mass motorand thin, long pump units as the experimental model. There are certain limitations in controlling the amplitudeof the pump unit with two-plane balancing considering the vibration response due to the imbalancein the conventional motor unit. Balancing techniques are required to effectively reduce the vibrationresponse due to an imbalance in the motor unit and mode of the pump unit. Therefore, in thisstudy, four sensors were added to the pump unit to consider their effects on the motor unit and modeto determine dedicated balancing techniques using the impact coefficient method after data acquisition.

키워드

LNG 2차 고압펌프양면 밸런싱불평형3점지지영향계수법Secondary High-pressure LNG PumpTwo-plane BalancingUnbalanceThree Points SupportInfluence Coefficient Method
제목
Real Scale Test Rotor를 이용한 3점지지 밸런싱에 관한 연구
제목 (타언어)
Study on Three-point Support Balancing using Real Scale Test Rotor
저자
박성훈손민아박동희최병근
DOI
10.5050/KSNVE.2019.29.2.216
발행일
2019
저널명
한국소음진동공학회논문집
29
2
페이지
216 ~ 221