Characterization of thermoluminescence of chip cards for emergency dosimetry
  • Kim, Hyoungtaek
  • Kim, Min Chae
  • Lee, Jungil
  • Discher, Michael
  • Woda, Clemens
  • ... Chung, Kisoo
  • 외 4명
Citations

WEB OF SCIENCE

11
Citations

SCOPUS

11

초록

The thermoluminescence of different chip cards was measured and analyzed for emergency dosimetry. Three SIM cards that are commonly found in mobile communication providers in South Korea and three smart IC cards that can be purchased online were used for the experiment. Chemical element analysis based on EDS mapping images was carried out and different weight percent of silica was found for each chip card. Glow curves of radiation induced signals through different combinations of optical filters showed blue or red emissions depending on chip cards. Sensitivity change resulting from the thermal stimulation was found to be 1.8 +/- 0.27 and 0.5 +/- 0.06 for the blue and red emission, respectively. In addition, signal fading resulted in more than 20% of the initial signal remaining 20 days after irradiation, when the 100-150 degrees C signal is used. Furthermore, the dose response was recorded from 50 mGy to 10 Gy for each chip card.

키워드

Emergency dosimetryChip cardThermoluminescenceEDS mapping ImageOptical filterMOBILE PHONESACCIDENT
제목
Characterization of thermoluminescence of chip cards for emergency dosimetry
저자
Kim, HyoungtaekKim, Min ChaeLee, JungilDischer, MichaelWoda, ClemensLim, SangyeobChang, InsuLee, Seung KyuKim, Jang-LyulChung, Kisoo
DOI
10.1016/j.radmeas.2020.106321
발행일
2020-06
유형
Article; Proceedings Paper
저널명
Radiation Measurements
134