관가정의 창면적비와 주광률 검토를 통한 자연채광 성능 분석
Analysis of Natural Lighting Performance of Kwangajeong according to Window-to-Wall Ratios and Daylighting Factors
- 정창헌;
- 박병용;
- 류성용
초록
This study evaluated natural lighting performance of Kwangajeong, the traditional housing in South Korea. Window-to-wall ratios were calculated by using the drawing documents. Daylighting factors were determined by field measurement. The results indicate that daylighting factor of the Kwangajeong is slightly low comparing present sustainable building design guide in South Korea even though the window-to-wall ratios are relatively high. It is thought that the relatively low daylighting factor are resulted by the low transmittance of Changhoji, the paper used on windows and Cheoma, eaves of the roof.
키워드
관가정; 주광률; 자연채광; 실측; 창면적비; Kwangajeong; Daylighting factor; Natural lighting; Field measurement; Window-to-wall ratio
- 제목
- 관가정의 창면적비와 주광률 검토를 통한 자연채광 성능 분석
- 제목 (타언어)
- Analysis of Natural Lighting Performance of Kwangajeong according to Window-to-Wall Ratios and Daylighting Factors
- 저자
- 정창헌; 박병용; 류성용
- 발행일
- 2019
- 저널명
- 한국건축친환경설비학회 논문집
- 권
- 13
- 호
- 4
- 페이지
- 281 ~ 289
- 언어
- KOR
- 출판사
- 한국건축친환경설비학회
- 발행국가
- 대한민국
- 분량
- 9 페이지
- ISSN
- E 2586-0666
P 1976-6483