폭발 하중에 대한 FRP 재킷 시스템이 보강된 철근콘크리트 기둥 해석 모델 개발

Numerical Model of FRP Jacketed RC Column Under Blast Loading Scenario

초록

This paper aims to develop numerical models for seismically-deficient reinforced concrete columns retrofitted using a fiber-reinforced polymer jacketing system under blast loading scenarios. To accomplish the research goal, a coupling model reproducing blast loads was developed and implemented to the column model. The column model was validated with a past experimental study, and the blast responses were compared to the numerical responses produced by past researchers. The validated modeling method was implemented to the non-retrofitted and retrofitted column models to estimate the effectiveness of the retrofit system. Based on the numerical responses, the retrofit system can significantly reduce the peak dynamic responses under a given blast loading scenario.

키워드

Blast loadSeismically-deficient reinforced concrete columnFiber-reinforced polymer jacketing systemEffectiveness of retrofit system
제목
폭발 하중에 대한 FRP 재킷 시스템이 보강된 철근콘크리트 기둥 해석 모델 개발
제목 (타언어)
Numerical Model of FRP Jacketed RC Column Under Blast Loading Scenario
저자
신지욱
DOI
10.9712/KASS.2021.21.2.81
발행일
2021-06
저널명
한국공간구조학회지
21
2
페이지
67 ~ 79