외단열 동시타설 공법에서 단열재 부착강도에 관한 연구

A Study on the Bond Strength between Exterior Insulation Board and Cast-in-place Concrete

초록

In Korea, there have been recently many studies to overcome weaknesses of exterior insulation in terms of workability and safety at high-rise building. And, the exterior insulation board in cast-in-place concrete form system was developed such as permanent insulation form system or integrated system for exterior insulation and wall. We utilized modified method for KS F 2762 to obtain test result for insulation bond strength in this study. Based on this method, we had measurements of bond strength for 12 cases and analyzed the result value of insulation bond strength test. In result, bond strength of EPS(expanded poly styrene, ‘B’ company) in E/F case is nearly 0.08 N/mm2(reference value of EOTA). Considering strong wind load by typhoon in Korea, it is necessary to use connection elements or to improve the bond strength of insulation by ribbed surface.

키워드

Exterior Insulation Board in Cast-in-place Concrete Form System; Insulation Bond Strength; Connection Element; 외단열 동시타설 공법; 단열재 부착강도; 결합부재
제목
외단열 동시타설 공법에서 단열재 부착강도에 관한 연구
제목 (타언어)
A Study on the Bond Strength between Exterior Insulation Board and Cast-in-place Concrete
저자
류성용; 정창헌; 서혜수
발행일
2016
저널명
한국건축친환경설비학회 논문집
권
10
호
6
페이지
437 ~ 442