CFD analysis of flow phenomena inside thermo vapor compressor influenced by operating conditions and converging duct angles

  • Jeong, Hyomin; 
  • Utomo, Tony; 
  • Ji, Myoungkuk; 
  • Lee, Yonghun; 
  • Lee, Gyeonghwan; 
  • 외 1명
Citations

WEB OF SCIENCE

20
Citations

SCOPUS

25

초록

A thermo vapor compressor is simply a steam ejector employed in a multi effect desalination process. A greater understanding of flow phenomena inside an ejector plays an important role in its performance improvement. In this paper, CFD investigation has been carried out to study the flow structure inside a steam ejector. This research revealed the influence of operating pressures and ejector geometries on the flow structure and the performance of a steam ejector. The CFD results were verified with available experimental data. The angle of the converging duct as the geometry parameter was varied as 0A degrees, 0.5A degrees, 1A degrees, 2A degrees, 3.5A degrees and 4.5A degrees. The best performance was obtained by the ejector with converging duct angle of 1A degrees.

키워드

Thermo vapor compressor; Steam ejector; Performance; CFD; Desalination; COMPUTATIONAL FLUID-DYNAMICS; EJECTOR; SYSTEM; PERFORMANCE
제목
CFD analysis of flow phenomena inside thermo vapor compressor influenced by operating conditions and converging duct angles
저자
Jeong, Hyomin; Utomo, Tony; Ji, Myoungkuk; Lee, Yonghun; Lee, Gyeonghwan; Chung, Hanshik
DOI
10.1007/s12206-009-0626-7
발행일
2009-09
유형
Article
저널명
Journal of Mechanical Science and Technology
권
23
호
9
페이지
2366 ~ 2375