면외변형의 영향을 받는 알루미늄합금 일면전단 볼트접합부의 내력평가에 관한 실험적 연구

An Experimental Study on Ultimate Strength of Aluminum Alloy Single Shear Bolted Connections with Curling Influence

초록

Many researchers have studied the structural performance of bolted connection with aluminum alloys and design specifications for in-plane fracture (net-section, bearing and block shear fractures) of bolted connection have been improved by their study results. However, it can be known from study results conducted by Kim et al. that curling (out-of-plane deformation) could be negative effect (strength reduction) on ultimate strength of single shear bolted connection fabricated with 3.0mm thick aluminum alloy(6061-T6) plate. Strength reduction for curled single shear specimens obtained from the comparison of test results for double shear bolted connections ranged from 4% to 30%. In this paper, additional experiments are performed in order to investigate the influence of curling on ultimate strength and curling occurrence condition for 4.0mm thick bolted connection. Main variables are end distance and edge distance. In all specimens, strength reduction by curling was observed. Strengths obtained from test results were compared with design strengths predicted by AISI (American Iron and Steel Institute) and AAA (American Aluminum Association) design rules. Bearing factor considering curling effect and hole deformation limit was discussed.

키워드

박판 알루미늄합금; 볼트접합; 최대내력; 면외변형; 지압계수; Thin-walled Aluminum Alloys; Bolted connection; Ultimate strength; Curling; Bearing factor
제목
면외변형의 영향을 받는 알루미늄합금 일면전단 볼트접합부의 내력평가에 관한 실험적 연구
제목 (타언어)
An Experimental Study on Ultimate Strength of Aluminum Alloy Single Shear Bolted Connections with Curling Influence
저자
강현식; 김태수
DOI
10.5659/JAIK_SC.2015.31.4.71
발행일
2015
저널명
대한건축학회논문집 구조계
권
31
호
4
페이지
71 ~ 78