자동차용 수소 차단밸브의 개폐에 따른 열전달 특성
Heat Transfer Characteristics According to the Opening and Closing of Hydrogen Shut-off Valve for Automobiles

초록

In this study, a numerical analysis study on the heat transfer characteristics according to the opening and closing of the hydrogen shut-off valve was performed, and the temperature distribution of the key components of the hydrogen shut-off valve was predicted through the result. The ANSYS CFX program was used to predict the heat transfer characteristics of the hydrogen shut-off valve. When the hydrogen shut-off valve was open, the average temperature of the O-ring, which prevents hydrogen leak inside the solenoid valve, was approximately -40℃, and the plunger showed a maximum of -40℃ and a minimum of -110℃. When the hydrogen shut-off valve was completely closed, the O-ring showed approximately 24.82℃ and the plunger showed approximately 24.71℃, which were almost at room temperature.

키워드

Heat TransferHydrogenNumerical AnalysisOpening and ClosingShut-off ValveSolenoid Valve열전달수소수치해석개폐차단밸브솔레노이드 밸브
제목
자동차용 수소 차단밸브의 개폐에 따른 열전달 특성
제목 (타언어)
Heat Transfer Characteristics According to the Opening and Closing of Hydrogen Shut-off Valve for Automobiles
저자
김나용김문학이치우
DOI
10.17958/ksmt.27.2.202504.305
발행일
2025-04
저널명
한국기계기술학회지
27
2
페이지
305 ~ 311