In this study, a numerical analysis study on the heat transfer characteristics according to the opening and closing of the hydrogen shut-off valve was performed, and the temperature distribution of the key components of the hydrogen shut-off valve was predicted through the result. The ANSYS CFX program was used to predict the heat transfer characteristics of the hydrogen shut-off valve. When the hydrogen shut-off valve was open, the average temperature of the O-ring, which prevents hydrogen leak inside the solenoid valve, was approximately -40℃, and the plunger showed a maximum of -40℃ and a minimum of -110℃. When the hydrogen shut-off valve was completely closed, the O-ring showed approximately 24.82℃ and the plunger showed approximately 24.71℃, which were almost at room temperature.
키워드
- 제목
- 자동차용 수소 차단밸브의 개폐에 따른 열전달 특성
- 제목 (타언어)
- Heat Transfer Characteristics According to the Opening and Closing of Hydrogen Shut-off Valve for Automobiles
- 저자
- 김나용; 김문학; 이치우
- 발행일
- 2025-04
- 저널명
- 한국기계기술학회지
- 권
- 27
- 호
- 2
- 페이지
- 305 ~ 311