상세 보기
Experimental study of the natural convection characteristics of finned-tube sodium-to-air heat exchanger
- Lee, Jewhan;
- Min, Jaehong;
- Yoon, Jung;
- Kim, Hyungmo
WEB OF SCIENCE
4SCOPUS
4초록
The finned-tube sodium-to-air heat exchanger plays a crucial role in ensuring the safety of prototype Gen IV sodium-cooled fast reactors. It is designed to actively operate with power, but it is also important to consider its passive performance to ensure availability during power-out conditions. This study focused on addressing this limitation through a natural convection experiment using a dedicated facility, and the obtained results were compared with the safety analysis code MARS-LMR. The overall temperature difference was observed to be within an acceptable range of less than 5 %. While the code calculations aligned well with the experimental results at higher temperatures, they underestimated the experimental results at lower temperatures. These findings can serve as a basis for other codes employing different heat transfer correlations and for future reactor licensing purposes. © The Korean Society of Mechanical Engineers and Springer-Verlag GmbH Germany, part of Springer Nature 2024.
키워드
- 제목
- Experimental study of the natural convection characteristics of finned-tube sodium-to-air heat exchanger
- 저자
- Lee, Jewhan; Min, Jaehong; Yoon, Jung; Kim, Hyungmo
- 발행일
- 2024-04
- 유형
- Article
- 권
- 38
- 호
- 4
- 페이지
- 2055 ~ 2062