상세 보기
초록
This study performed high-frequency heat treatment experiments and simulations of the park gear of an automobile transmission. The heating temperature and hardening depth were measured during high-frequency heat treatment. Moreover, by applying the resonance RCL circuit, the current value of the coil during high-frequency heat treatment, the electromagnetic and heat transfer material properties dependent on the temperature, and the phase transformation function were all applied to the simulation. In the high-frequency heat treatment experiment, the heating temperature was 977.4oC and the 1st direction hardening depth was 1.5 mm, the 2nd direction hardening depth was 3 mm, and the 3rd direction hardening depth was 2.5 mm, and the reliability was verified by comparing the simulation heating temperature of 1,097oC and the 1st direction predicted hardening depth of 1.6 mm, the 2nd direction predicted hardening depth of 2.8 mm, and the 3rd direction predicted hardening depth of 2.7 mm. The error rate of the heating temperature results was 12.2% whereas that of the hardening depth results was 7.1%.
키워드
- 제목
- 코일전류 계산 및 AISI 1552 상변태를 고려한 주차기어의 고주파 열처리 시뮬레이션
- 제목 (타언어)
- High-frequency Heat Treatment Simulation of Park Gear considering Coil Current Calculation and AISI 1552 Phase Transformation
- 저자
- 최진규; 이석순
- 발행일
- 2023-05
- 저널명
- 한국정밀공학회지
- 권
- 40
- 호
- 5
- 페이지
- 399 ~ 407
- 언어
- KOR
- 출판사
- 한국정밀공학회
- 발행국가
- 대한민국
- 분량
- 9 페이지
- ISSN
- E 2287-8769
P 1225-9071