Physical modifications for improving inlet flow distribution evenness in multiple parallel-arrayed membrane modules

  • Park, Jiyeong
  • Yoon, Sukmin
  • Kim, Seung-Joon
  • Park, No-Suk
Citations

WEB OF SCIENCE

3
Citations

SCOPUS

2

초록

This study was conducted to validate a proposed hydraulic modification for improving the evenness of the inlet flow distribution in a manifold pipe in a water treatment system in which the treated water flows in parallelly arranged membrane modules, by performing computational fluid dynamics (CFD) simulations and experiments. The results of the CFD simulations confirmed that the coefficient of variation of the flow rate distribution in the manifold pipe could be reduced by approximately 47% by installing an inner orifice pipe within the header pipe (double header pipe). In addition, the experimental results showed that the coefficient of variation was reduced by 67% for a double header pipe compared with a single header pipe. Furthermore, when the diameter of the inner orifice pipe was identical to that of the branch pipe connected to the external header pipe, the flow distribution evenness was maximized.

키워드

Inlet flow distribution evennessComputational fluid dynamicsParallel arranged membrane modulesDouble header pipeSingle header pipeFUEL-CELL STACKSMANIFOLDSCHANNEL
제목
Physical modifications for improving inlet flow distribution evenness in multiple parallel-arrayed membrane modules
저자
Park, JiyeongYoon, SukminKim, Seung-JoonPark, No-Suk
DOI
10.5004/dwt.2018.22148
발행일
2018-07
유형
Article; Proceedings Paper
저널명
Desalination and Water Treatment
119
페이지
1 ~ 8