배관공진에 의한 구조물 진동 분석

Structural Vibration Analysis Caused by Piping Resonance

초록

A few intake stations have vibration problems caused by pumps, motors and pipes. The vibration transferred from pumps, motors and pipes excites building severely. Therefore, the crack is generated on building wall and people who work at intake station are damaged. In this paper, the vibration has been measured and analyzed for pumps, motors, pipes and building at intake station. Also, the cause of vibration is identified. Finally, the solution of structural vibration is established using the results of measurement.

키워드

Intake Station(취수장); Crack(균열); Reference(기준); Vane Passing Frequency(깃 통과 주파수); Intake Station(취수장); Crack(균열); Reference(기준); Vane Passing Frequency(깃 통과 주파수)
제목
배관공진에 의한 구조물 진동 분석
제목 (타언어)
Structural Vibration Analysis Caused by Piping Resonance
저자
최병근; 구동식; 김효중; 정한얼; 김학은
발행일
2007
저널명
대한기계학회논문집 A
권
31
호
2
페이지
190 ~ 196