임펠러 타입 계량 밸브 입·출구 차압에 따른 유동해석에 관한 연구
A Study on the Flow Analysis of Impeller type Measuring Valve according to Differential Pressure at Inlet and Outlet
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

This study conducts the flow analysis on the basis of the impeller RPM of water measuring valve and differential pressure at valve inlet and outlet. The software used for the flow analysis is STAR-CCM+. In terms of the structure of the measuring valve, it has an impeller installed inside, and a metering chamber has inlet and outlet holes. The flow analysis on the water measuring valve drew the following conclusions: The flow rate and flow coefficient distribution according to the impeller RPM and differential pressure were on the linear increase. Regarding the flow field in the valve, the increased differential pressure had the highest velocity distribution, and complex flow field was generated in the measuring chamber. In particular, since the path between the inlet and outlet holes in the measuring chamber and the valve body was narrow, there was a section that had flow field interference. Given that, it showed the feature of the valve used for water measuring on the basis of the impeller RPM.

키워드

Measuring ValveValve Flow CoefficientImpellerFlow AnalysisDifferential Pressure
제목
임펠러 타입 계량 밸브 입·출구 차압에 따른 유동해석에 관한 연구
제목 (타언어)
A Study on the Flow Analysis of Impeller type Measuring Valve according to Differential Pressure at Inlet and Outlet
저자
김태준이중섭이치우
발행일
2023-06
저널명
한국산업융합학회논문집
26
3
페이지
381 ~ 387