This study numerically analyzed the icing process in a U-shaped pipe exposed to the outside by considering the mushy zone of freezing water. Numerical results showed that the flow was pulled outward due to the U-shaped bend in the freezing section exposed to the outside, which resulted in the ice wave formation on the wall of the bended pipe behind. At the same time, the formation of a corrugated ice layer became apparent due to the venturi effect caused by the ice. The factors affecting the freezing were investigated, including the change of the pipe wall temperature, the water inflow velocity, and the pipe bend spacing. It was found that, as a whole, the thickness of the freezing layer increased as the pipe wall temperature decreased. It was also found that the freezing layer became relatively thin when the inflow rate of water was increased, and that the spacing of the pipe bends did not significantly impact the change in the freezing layer.
키워드
- 제목
- U자형 배관 내 결빙에 대한 해석적 연구
- 제목 (타언어)
- Numerical Analysis of Freezing Phenomena of Water in a U-Type Tube
- 저자
- 박용석; 서정세
- 발행일
- 2019
- 저널명
- 한국기계가공학회지
- 권
- 18
- 호
- 12
- 페이지
- 52 ~ 58